Maestro M100 2G Manual de usuario Pagina 69

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 87
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 68
Confidential, the whole present document is the sole property of Maestro Wireless Solution Ltd.
67
20.2 Counter Service
Counter is used to execute a Command String when the Counter value equals a preset value. There are total of 5
Counters.
20.2.1 Counter Service Command String Syntax and explanation
1
st
field
Service
type
2
nd
field
Service id
3
rd
field
Operation
type
4
th
field
Operation
argument
Explanation
CT
(1 to 5)
DE
1 TO 255
Decrement the value of Counter with
argument value
IN
1 TO 255
Increment the value of Counter with
argument value
RS
0
Reset the Counter value to zero
ST
-32768 to
32767
Set the “trigger” value
If Counter value equal this value, will
execute Command String
TR
(1 to 50)
0
Set Command String to be run, 0 to
cancel setting
Example: Set Counter #1 to execute Command String #10 if Counter value equal 100
CT 1 ST 100 CT 1 TR 10
Example: Increase Counter #1 value by 20
CT 1 IN 20
Example: Reset Counter #1 value to 0
CT 1 RS 0
Note
:
Initial Counter and trigger values are zero.
The Counter is recorded by a signed 16 bit register, if the Counter value is 32767 and you increase it by 1, the value
will change to -32768
There is no limit on no. of times of triggering. E.g. If you first set trigger value to 2 and reset Counter to 0, then you
increment counter by 2, then decrement by 2 and increment by 2 again. Then the associated Command String will be
executed twice.
20.2.2 Reading Counter Service Status
See Chapter for details.
20.3 Countdown Timer Service
Countdown Timer is used execute a Command String when the Timer value reach zero. Counting period is 1 second.
There are total of 10 Countdown Timers.
20.3.1 Countdown Timer Service Command String Syntax and explanation
1
st
field
Service
type
2
nd
field
Service id
3
rd
field
Operation
type
4
th
field
Operation
argument
Explanation
TM
(1 to 10)
ST
1 TO
2147483647
Initial value of Countdown Timer (in
seconds)
SW
0 TO 1
Start (1) or Stop (0) Timer
TR
(1 to 50)
0
Set Command String to be run, 0 to
cancel setting